FUNCTIONAL DEVICE OPERATION
OPERATING MODES
Table 33. LDO Regulator Control (Internal Pass Device LDOs)
VxEN
0
1
1
1
VxSTBY
X
0
1
1
STANDBY
X
X
0
1
Regulator Vx
Off
On
On
Off
Notes
61. This table is valid for regulators with an internal pass device
62. STANDBY refers to a Standby event as described earlier
BUCK REGULATORS
Operational modes of the Buck regulators can be controlled by direct SPI programming, altered by the state of the STANDBY
pins, by direct state machine influence, or by load current magnitude when so configured. Available modes include PWM with
No Pulse Skipping (PWM), PWM with Pulse Skipping (PWMPS), Pulse Frequency Mode (PFM), and Off. The transition between
the two modes PWMPS and PFM can occur automatically, based on the load current. Therefore, no specific control is required
to put the switchers in a Low-power mode. When the buck regulators are not configured in the Auto mode, power savings may
be achieved by disabling switchers when not needed, or running them in PFM mode if loading conditions are light enough.
SW1, SW2, SW3, and SW4 can be configured for mode switching with STANDBY or autonomously based on load current with
adaptive mode control (Auto). Additionally, provisions are made for maintaining PFM operation in USEROFF and MEMHOLD
modes to support state retention for faster startup from the Low-power Off modes for Warm Start or Warm Boot.
Table 34 summarizes the Buck regulator programmability for Normal and Standby modes.
Table 34. Switcher Mode Control for Normal and Standby Operation
SWxMODE[3:0]
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Normal mode (63)
Off
PWM
PWMPS
PFM
Auto
PWM
PWM
NA
Auto
PWM
PWMPS
PWMPS
Auto
PWM
PWMPS
PFM
Standby Mode (63)
Off
Off
Off
Off
Off
PWM
Auto
NA
Auto
PWMPS
PWMPS
Auto
PFM
PFM
PFM
PFM
Notes
63. STANDBY defined as logical AND of STANDBY and STANDBYSEC pin
In addition to controlling the operating mode in Standby, the voltage setting can be changed. The transition in voltage is
handled in a controlled slope manner, see Supplies , for details. Each switcher has an associated set of SPI bits for Standby mode
set points. By default the Standby settings are identical to the non-Standby settings, which are initially defined by PUMS
programming.
The actual operating mode of the switchers as a function of STANDBY pins is not reflected through the SPI. The SPI will read
back what is programmed in SWxMODE[3:0], not the actual state that may be altered as described previously.
Table 35 and Table 36 show the switcher mode control in the Low-power Off states. Note that a Low-power Off activated SWx
should use the Standby set point as programmed by SWxSTBY[4:0]. The activated switcher(s) will maintain settings for mode
and voltage until the next startup event. When the respective time slot of the startup sequencer is reached for a given switcher,
its mode and voltage settings will be updated the same as if starting out of the Off state (except that switchers active through a
Low-power Off mode will not be off when the startup sequencer is started).
MC13892
Analog Integrated Circuit Device Data
66
Freescale Semiconductor
相关PDF资料
PDF描述
KIT17C724EPEVBE KIT FOR 17C7242CH HBRIDGE PWR IC
KIT33810EKEVME BOARD EVAL FOR MC33810
KIT33811EGEVBE KIT EVAL 33811 SOLENOID MON IC
KIT33812ECUEVME KIT DESIGN FOR 33812/S12P
KIT33812EKEVBE BOARD EVALUATION FOR MC33812
相关代理商/技术参数
参数描述
KIT-1395 制造商:Anderson Power Products (APP) 功能描述:KIT
Kit-1395G1 制造商:ANDERSON POWER PRODUCTS 功能描述:KIT
Kit-1395G10 制造商:ANDERSON POWER PRODUCTS 功能描述:KIT
Kit-1395G2 制造商:ANDERSON POWER PRODUCTS 功能描述:KIT
Kit-1395G3 制造商:ANDERSON POWER PRODUCTS 功能描述:KIT