参数资料
型号: ADE7878ACPZ
厂商: Analog Devices Inc
文件页数: 42/100页
文件大小: 0K
描述: IC ENERGY METERING 3PH 40LFCSP
标准包装: 1
输入阻抗: 400 千欧
测量误差: 0.2%
电压 - 高输入/输出: 2.4V
电压 - 低输入/输出: 0.4V
电源电压: 2.4 V ~ 3.7 V
测量仪表类型: 3 相
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 40-WFQFN 裸露焊盘,CSP
供应商设备封装: 40-LFCSP-WQ(6x6)
包装: 托盘
ADE7854/ADE7858/ADE7868/ADE7878
–50 –45 –40 –35 –30 –5 –20 –15 –10 –5 0 5 10 15 20 25 30 35 40 45 50
HOT TEMPERATURE COEFFICIENT (ppm/°C)
Figure 58. Histogram of the Reference Drift from 25°C to 85°C
Because the reference is used for all ADCs, any x% drift in the
reference results in a 2x% deviation of the meter accuracy. The
reference drift resulting from temperature changes is usually very
small and, typically, much smaller than the drift of other
components on a meter.
The ADE7854 / ADE7858 / ADE7868 / ADE7878 use the internal
voltage reference when Bit 0 (EXTREFEN) in the CONFIG2
register is cleared to 0 (the default value); the external voltage
reference is used when the bit is set to 1. Set the CONFIG2 register
during the PSM0 mode; its value is maintained during the PSM1,
PSM2, and PSM3 power modes.
DIGITAL SIGNAL PROCESSOR
The ADE7854 / ADE7858 / ADE7868 / ADE7878 contain a fixed
Data Sheet
memory RAM are initialized at 0, their default values, and they
can be read/written without any restriction. The run register,
used to start and stop the DSP, is cleared to 0x0000. The run
register needs to be written with 0x0001 for the DSP to start
code execution.
To protect the integrity of the data stored in the data memory
RAM of the DSP (addresses between 0x4380 and 0x43BE),
a write protection mechanism is available. By default, the
protection is disabled and registers placed between 0x4380 and
0x43BE can be written without restriction. When the protection
is enabled, no writes to these registers is allowed. Registers can
be always read, without restriction, independent of the write
protection state.
To enable the protection, write 0xAD to an internal 8-bit
register located at Address 0xE7FE, followed by a write of 0x80
to an internal 8-bit register located at Address 0xE7E3.
It is recommended to enable the write protection after the
registers have been initialized. If any data memory RAM based
register needs to be changed, simply disable the protection,
change the value and then re-enable the protection. There is
no need to stop the DSP to change these registers.
To disable the protection, write 0xAD to an internal 8-bit
register located at Address 0xE7FE, followed by a write of 0x00
to an internal 8-bit register located at Address 0xE7E3.
The recommended procedure to initialize the ADE7854 /
ADE7858 / ADE7868 / ADE7878 registers at power up is as
follows:
function digital signal processor (DSP) that computes all powers
and rms values. It contains program memory ROM and data
memory RAM.
The program used for the power and rms computations is
stored in the program memory ROM and the processor executes
it every 8 kHz. The end of the computations is signaled by
setting Bit 17 (DREADY) to 1 in the STATUS0 register. An
interrupt attached to this flag can be enabled by setting Bit 17
(DREADY) in the MASK0 register. If enabled, the IRQ0 pin is
set low and Status Bit DREADY is set to 1 at the end of the
computations. The status bit is cleared and the IRQ0 pin is set
to high by writing to the STATUS0 register with Bit 17 (DREADY)
set to 1.
The registers used by the DSP are located in the data memory
RAM, at addresses between 0x4380 and 0x43BE. The width of
this memory is 28 bits. Within the DSP core, the DSP contains a
two stage pipeline. This means that when a single register needs
to be initialized, two more writes are required to ensure the
value has been written into RAM, and if two or more registers
need to be initialized, the last register must be written two more
times to ensure the value has been written into RAM.
As explained in the Power-Up Procedure section, at power-up
or after a hardware or software reset, the DSP is in idle mode.
No instruction is executed. All the registers located in the data
?
?
?
?
?
?
?
?
Initialize the AIGAIN, BIGAIN, CIGAIN, and NIGAIN
registers.
Start the DSP by setting run = 1.
Initialize all the other data memory RAM registers. Write
the last register in the queue three times to ensure its
value was written into the RAM. Initialize all of the other
ADE7854 / ADE7858 / ADE7868 / ADE7878 registers with the
exception of the CFMODE register.
Read the energy registers xWATTHR, xFWATTHR,
xVARHR, xFVARHR, and xVAHR to erase their content
and start energy accumulation from a known state.
Clear Bit 9 (CF1DIS), Bit 10 (CF2DIS), and Bit 11
(CF3DIS) in the CFMODE register to enable pulses at
the CF1, CF2, and CF3 pins. Do this initialization last,
so no spurious pulses are generated while the ADE7854 /
ADE7858 / ADE7868 / ADE7878 are initialized.
Enable the write protection by writing 0xAD to an internal
8-bit register located at Address 0xE7FE, followed by a write of
0x80 to an internal 8-bit register located at Address 0xE7E3.
Read back all data memory RAM registers to ensure they
were initialized with the desired values.
In the remote case that one or more registers are not initia-
lized correctly, disable the protection by writing 0xAD to
Rev. H | Page 42 of 100
相关PDF资料
PDF描述
GBC06DREI-S13 CONN EDGECARD 12POS .100 EXTEND
VI-J60-CX-F4 CONVERTER MOD DC/DC 5V 75W
ECA10DCBT CONN EDGECARD 20POS R/A .125 SLD
EL7242CSZ-T13 IC DRIVER MOSFET DUAL HS 8-SOIC
ADE7169ASTZF16 IC ENERGY METER 1PHASE 64LQFP
相关代理商/技术参数
参数描述
ADE7878ACPZ 制造商:Analog Devices 功能描述:IC MULTIFUNCTION ENERGY METERING LFCSP40
ADE7878ACPZ-RL 功能描述:IC ENERGY METERING 3PH 40LFCSP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7878XCPZ 制造商:Analog Devices 功能描述:POLY PHASE MULTIFUNCTION ENERGY METERING IC WITH TOTAL - Bulk
ADE7880 制造商:Analog Devices 功能描述:BOARD EVAL ENERGY METER ADE
ADE7880ACPZ 功能描述:IC ENERGY METERING 3PH 40LFCSP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*