描述: IC ENERGY METERING 3PH 40LFCSP
标准包装: 1
输入阻抗: 400 千欧
测量误差: 0.2%
电压 - 高输入/输出: 2.4V
电压 - 低输入/输出: 0.4V
电源电压: 2.4 V ~ 3.7 V
测量仪表类型: 3 相
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 40-WFQFN 裸露焊盘,CSP
供应商设备封装: 40-LFCSP-WQ(6x6)
包装: 托盘
ADE7854/ADE7858/ADE7868/ADE7878
ZXSEL[0] IN
LCYCMODE[7:0]
ZERO-
CROSSING
DETECTION
(PHASE A)
Data Sheet
Because the active power is integrated on an integer number of
half-line cycles in this mode, the sinusoidal components are
reduced to 0, eliminating any ripple in the energy calculation.
Therefore, total energy accumulated using the line cycle
ZXSEL[1] IN
LCYCMODE[7:0]
LINECYC[15:0]
accumulation mode is
ZERO-
CROSSING
DETECTION
CALIBRATION
CONTROL
e =
t + nT ∞
∫ p ( t ) dt = nT ∑ V k I k
t k = 1
cos( φ k – γ k )
(28)
(PHASE B)
ZXSEL[2] IN
LCYCMODE[7:0]
ZERO-
CROSSING
DETECTION
(PHASE C)
AWATTOS
where nT is the accumulation time.
Note that line cycle active energy accumulation uses the same
signal path as the active energy accumulation. The LSB size of
these two methods is equivalent.
REACTIVE POWER CALCULATION— ADE7858 ,
ADE7868 , ADE7878 ONLY
AWGAIN
OUTPUT
FROM LPF2
ACCUMULATOR
WTHR[47:0]
AWATTHR[31:0]
32-BIT
REGISTER
The ADE7858 / ADE7868 / ADE7878 can compute the total
reactive power on every phase. Total reactive power integrates
all fundamental and harmonic components of the voltages and
currents. The ADE7878 also computes the fundamental reactive
Figure 70. Line Cycle Active Energy Accumulation Mode
The line cycle energy accumulation mode is activated by setting
Bit 0 (LWATT) in the LCYCMODE register. The energy accu-
mulation over an integer number of half line cycles is written
to the watt-hour accumulation registers after LINECYC number
of half line cycles is detected. When using the line cycle
accumulation mode, the Bit 6 (RSTREAD) of the LCYCMODE
register should be set to Logic 0 because the read with reset of
watt-hour registers is not available in this mode.
Phase A, Phase B, and Phase C zero crossings are, respectively,
included when counting the number of half line cycles by setting
power, the power determined only by the fundamental
components of the voltages and currents.
A load that contains a reactive element (inductor or capacitor)
produces a phase difference between the applied ac voltage and
the resulting current. The power associated with reactive elements
is called reactive power, and its unit is VAR. Reactive power is
defined as the product of the voltage and current waveforms when
all harmonic components of one of these signals are phase
shifted by 90°.
Equation 31 gives an expression for the instantaneous reactive
power signal in an ac system when the phase of the current
channel is shifted by +90°.
v ( t ) = ∑ V k 2 sin( kωt + φ k )
i ( t ) = ∑ I k 2 sin ( k ω t + γ k )
i ' ( t ) = ∑ I k 2 sin ? ? k ω t + γ k +
π ?
2 ?
Bits[5:3] (ZXSEL[x]) in the LCYCMODE register. Any combi-
nation of the zero crossings from all three phases can be used
for counting the zero crossing. Select only one phase at a time
for inclusion in the zero crossings count during calibration.
The number of zero crossings is specified by the LINECYC 16-bit
unsigned register. The ADE78xx can accumulate active power
for up to 65,535 combined zero crossings. Note that the internal
k = 1
k = 1
k = 1 ?
?
(29)
(30)
zero-crossing counter is always active. By setting Bit 0 (LWATT)
in the LCYCMODE register, the first energy accumulation
result is, therefore, incorrect. Writing to the LINECYC register
when the LWATT bit is set resets the zero-crossing counter, thus
ensuring that the first energy accumulation result is accurate.
where i?(t) is the current waveform with all harmonic
components phase shifted by 90°.
Next, the instantaneous reactive power, q(t), can be expressed as
q(t) = v(t) × i?(t) (31)
q ( t ) = ∑ V k I k × 2 sin( kωt + φ k ) × sin( kωt + γ k +
π
∑ V k I m × 2sin( kωt + φ k ) × sin( mωt + γ m +
At the end of an energy calibration cycle, Bit 5 (LENERGY) in
the STATUS0 register is set. If the corresponding mask bit in
the MASK0 interrupt mask register is enabled, the IRQ0 pin
also goes active low. The status bit is cleared and the IRQ0 pin is
set to high again by writing to the STATUS0 register with the
corresponding bit set to 1.
k ≠ m
k = 1
k , m = 1 2
)
π
2
)+
Rev. H | Page 52 of 100
相关PDF资料
PDF描述
GBC06DREI-S13 CONN EDGECARD 12POS .100 EXTEND
VI-J60-CX-F4 CONVERTER MOD DC/DC 5V 75W
ECA10DCBT CONN EDGECARD 20POS R/A .125 SLD
EL7242CSZ-T13 IC DRIVER MOSFET DUAL HS 8-SOIC
ADE7169ASTZF16 IC ENERGY METER 1PHASE 64LQFP
相关代理商/技术参数
参数描述
ADE7878ACPZ 制造商:Analog Devices 功能描述:IC MULTIFUNCTION ENERGY METERING LFCSP40
ADE7878ACPZ-RL 功能描述:IC ENERGY METERING 3PH 40LFCSP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7878XCPZ 制造商:Analog Devices 功能描述:POLY PHASE MULTIFUNCTION ENERGY METERING IC WITH TOTAL - Bulk
ADE7880 制造商:Analog Devices 功能描述:BOARD EVAL ENERGY METER ADE
ADE7880ACPZ 功能描述:IC ENERGY METERING 3PH 40LFCSP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*