194
Register 056H: T1 XIBC Control
Bit
Type
Function
Default
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
R/W
R/W
EN
UF
0
0
X
X
X
X
0
0
Unused
Unused
Unused
Unused
CL1
CL0
R/W
R/W
When the E1/T1B bit of the Global Configuration register is a logic 1, this register
is held reset.
EN:
The EN bit controls whether the Inband Code is transmitted or not. A logic 1
in the EN bit position enables transmission of inband codes; a logic 0 in the
EN bit position disables inband code transmission.
UF:
The UF bit controls whether the code is transmitted framed or unframed. A
logic 1 in the UF bit position selects unframed inband code transmission; a
logic 0 in the UF bit position selects framed inband code transmission. Note:
the UF register bit controls the XBAS directly and is not qualified by the EN
bit. When UF is set to logic 1, the XBAS is disabled and no framing is
inserted regardless of the setting of EN. The UF bit should only be written to
logic 1 when the EN bit is set, and should be cleared to logic 0 when the EN
bit is cleared.
CL1, CL0:
The bit positions CL1 and CL0 of this register indicate the length of the
inband loopback code sequence, as follows:
Table 41
- Transmit In-band Code Length
CL1
CL0
Code Length
0
0
5