Data Sheet
GENERAL CALL SUPPORT
The ADP1046 is capable of decoding and acknowledging a
general call address. The general call address is supported for
send, write, and read commands that use Address 0x00 as the
slave address. The I 2 C slave responds to both its own address
and to the general call address (0x00).
Note that all commands start with a slave address with the R/W
bit cleared (set to 0), followed by the command code. This is
also true when using the general call address to communicate
with the I 2 C slave device.
10-BIT ADDRESSING
The ADP1046 does not support 10-bit addressing as defined in
the I 2 C specification.
FAST MODE
Fast mode (400 kB/sec) uses essentially the same mechanics
as the standard mode of operation; the electrical specifications
and timing are most affected. The I 2 C slave is capable of commu-
nicating with a master device operating in standard mode
(100 kB/sec) or fast mode.
REPEATED START CONDITION
In general, a repeated start condition is the absence of a stop
condition between two transfers. The two transfers can be of
any direction type, for example, a transmit followed by a receive
or a receive followed by a transmit. However, the ADP1046 I 2 C
communication protocol uses the repeated start condition only
when performing a read access (read byte, read word, and block
read). Other uses of the repeated start condition are not allowed.
ELECTRICAL SPECIFICATIONS
All logic complies with the electrical specifications outlined in the
Philips I 2 C Bus Specification , Version 2.1, dated January 2000.
FAULT CONDITIONS
The I 2 C protocol provides a very comprehensive set of fault
conditions that are monitored during communication. These
communication faults are error conditions associated with the
data transfer mechanism of the I 2 C protocol and are explained
in the following sections.
TIMEOUT CONDITION
A timeout condition occurs if any single SCL clock pulse is held
low for longer than the t TIMEOUT, MIN of 25 ms. Upon detecting the
timeout condition, the I 2 C slave device has 10 ms to abort the
transfer, release the bus lines, and be ready to accept a new start
condition. The device initiating the timeout is required to hold
the SCL clock line low for a minimum of t TIMEOUT, MAX = 35 ms,
guaranteeing that the slave device is given enough time to reset
its communication protocol.
ADP1046
DATA TRANSMISSION FAULTS
Data transmission faults occur when two communicating
devices violate the I 2 C communication protocol.
Sending Too Few Bits
Transmission is interrupted by a start or stop condition before
a complete byte (eight bits) has been sent. Not supported; any
transmitted data is ignored.
Reading Too Few Bits
Transmission is interrupted by a start or stop condition before
a complete byte (eight bits) has been read. Not supported; any
received data is ignored.
Host Sends or Reads Too Few Bytes
If a host ends a packet with a stop condition before the required
bytes are sent/received, it is assumed that the host intended to
stop the transfer. Therefore, the I 2 C slave does not consider this
to be an error and takes no action, except to flush any remain-
ing bytes in the transmit FIFO.
Host Sends Too Many Bytes
If a host sends more bytes than are expected for the corre-
sponding command, the I 2 C slave considers this a data
transmission fault and responds as follows:
? NACKs all unexpected bytes as they are received
? Flushes and ignores the received command and data
Host Reads Too Many Bytes
If a host reads more bytes than are expected for the corre-
sponding command, the I 2 C slave considers this a data
transmission fault and sends all 1s (0xFF) as long as the host
continues to request data.
Device Busy
The I 2 C slave device is too busy to respond to a request from the
master device. Typically SCL clock stretching is involved until
the device is free to communicate.
DATA CONTENT FAULTS
Data content faults occur when data transmission is successful,
but the I 2 C slave device cannot process the data that is received
from the master device.
Improperly Set Read Bit in the Address Byte
All I 2 C commands start with a slave address with the R/W bit
cleared (set to 0), followed by the command code. If a host
starts an I 2 C transaction with R/W set in the address phase
(equivalent to an I 2 C read), the I 2 C slave considers this a data
content fault and responds as follows:
? ACKs the address byte
? NACKs the command and data bytes
?
Sends all 1s (0xFF) as long as the host continues to
request data
Rev. B | Page 39 of 92
相关PDF资料
PDF描述
ADP1111ANZ-12 IC REG BUCK BST INV 12V .2A 8DIP
ADP121-ACBZ12R7 IC REG LDO 1.2V .15A 4WLCSP
ADP122AUJZ-2.9-R7 IC REG LDO 2.9V .3A 5TSOT
ADP124ARHZ-2.85-R7 IC REG LDO 2.85V .5A 8MSOP
ADP130AUJZ-2.5-R7 IC REG LDO 2.5V .35A TSOT-23-5
相关代理商/技术参数
参数描述
ADP1046ADC1-EVALZ 功能描述:电源管理IC开发工具 RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
ADP1046AWACPZ-R7 功能描述:Power Supply Controller Power Supplies 32-LFCSP-WQ (5x5) 制造商:analog devices inc. 系列:- 包装:剪切带(CT) 零件状态:有效 应用:电源 电压 - 输入:0 V ~ 1.6 V 电压 - 电源:3 V ~ 3.6 V 电流 - 电源:20mA 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:32-WFQFN 裸露焊盘,CSP 供应商器件封装:32-LFCSP-WQ(5x5) 标准包装:1
ADP1046DC1-EVALZ 功能描述:BOARD EVAL DAUGHTERCARD ADP1046 RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:- 标准包装:1 系列:PSoC® 主要目的:电源管理,热管理 嵌入式:- 已用 IC / 零件:- 主要属性:- 次要属性:- 已供物品:板,CD,电源
ADP1047 制造商:AD 制造商全称:Analog Devices 功能描述:Digital Power Factor Correction Controller
ADP1047-300-EVALZ 制造商:Analog Devices 功能描述:ANAADP1047-300-EVALZ 300W EVALUATION BOA 制造商:Analog Devices 功能描述:EVAL DIGITAL PFC CONTROLLER 300W 制造商:Analog Devices 功能描述:ADP1047, PFC CNTLR, 300W, EVAL KIT